DANOFELT PY 400   
Polyester geotextiles

 
 
Data Sheet Certificates Safety Data Sheet Commercial Sheet
 

DANOFELT PY 400 is a non-woven bonded by needle punching geotextile of 400 (+10%;-15%) g/m², composed of polyester short fibre. It has the CE trademark.

It is used for waterproofing protection of roofs, underground constructions and for land separation and filtration.

 Physical Properties

PHYSICAL PROPERTIESVALUEUNITSTANDARD
Average mass400 (+10%;-15%)g/m²UNE EN 965
Thickness under 2kPa pressure3.40, ±0.20mmUNE EN ISO 9863-1
Longitudinal tensile strength7.3, -0.3KN/mUNE EN ISO 10319
Tranversal tensile strength7.3, -0.3KN/mUNE EN ISO 10319
Longitudinal elongation at break110 ±20%UNE EN ISO 10319
Transversal elongation at break110±20%UNE EN ISO 10319
Puncture resistance (CBR)1.5, -0.3KNUNE EN ISO 12236
Dynamic perforation test4, +3mmUNE EN ISO 13433
Water permeability0.02771, -0.005m/sUNE EN ISO 11058
Waterflow capacity in their plane5.25 Exp-6, -0.1 Exp-7m²/sUNE EN ISO 12958
Opening size80, ±20µmUNE EN ISO 12956
Protection efficiency18.0 Exp3, -0.3 Exp3KN/m²PrEN 13719

 Addtitional Technical Data

ADDITIONAL DATA VALUEUNITSTANDARD
Thickness under 20 kPa pressure2,4, ±0,20mmUNE EN 9863-1
Thickness under 200 kPa pressure1,3, ±0,20mmUNE EN 9863-1

 Presentation

PRESENTATIONVALUEUNIT
Length80m
Width4.4m
Roll surface352m2
Product Code710451-

 Warning

The information contained in this document and any other advice provided, are given in good faith, based on DANOSA's current knowledge and experience when products are properly stored, handled and applied, in normal situations and in accordance with the recommendations of DANOSA. The information applies only to the application (s) and the product (s) to which reference is expressly made. In case of changes in the parameters of the application, or in case of a different application, consult the DANOSA Technical Service before using the DANOSA products. The information contained herein does not exonerate the responsibility of the building agents to test the products for the application and intended use, as well as their correct application in accordance with current legal regulations. The product images used in our communications are indicative and may differ slightly in color and aesthetic appearance in relation to the final product.
Orders are accepted in accordance with the terms of our current General Sales Conditions.
DANOSA reserves the right to modify, without prior notice, the data reflected in this documentation.

Website: www.danosa.com E-mail: info@danosa.com Telephone: +34 949 88 82 10


 Print