| TECHNICAL DATA | VALUE | UNIT | STANDARD |
| External fire performance | Broof(t1) | - | UNE-EN 1187; UNE-EN 13501-5 |
| Reaction to fire | E | - | UNE-EN 11925-2; UNE-EN 13501-1 |
| Watertightness | Pasa | - | UNE-EN 1928 |
| Longitudinal tensile strength | 700 ± 200 | N/5cm | UNE-EN 12311-1 |
| Transversal tensile strength | 450 ± 150 | N/5cm | UNE-EN 12311-1 |
| Longitudinal elongation at break | 25 ±15 | % | UNE-EN 12311-1 |
| Transversal elongation at break | 25 ±15 | % | UNE-EN 12311-1 |
| Resistance to root penetration | No Pasa | - | EN 13948 |
| Resistance to static loading | >15 | kg | UNE-EN 12730 |
| Resistance to impact | >1000 | mm | UNE-EN 12691 |
| Longitudinal resistance to tearing (nail shank) | NPD | N | UNE-EN 12310-1 |
| Transversal resistance to tearing (nail shank) | NPD | N | UNE-EN 12310-1 |
| Joint strength: peel resistance | PND | - | UNE-EN 12316-1 |
| Joint strength: shear resistance | 450 ± 150 | - | UNE-EN 12317-1 |
| Flexibility at low temperature | < -5 | ºC | UNE-EN 1109 |
| Humidity resistance factor | 20.000 | - | UNE-EN 1931 |
| Dangerous substances | NPD | - | - |
| Flexibility at low temperature (pliability) after aging | +5 ± 5 | ºC | UNE-EN 1109 |
| Flow resistance at elevated temperature after aging | 120 ±10 | ºC | UN-EN 1110 |